DMT
  • Products
    • Muscle Strip Systems >
      • Tissue Puller System - 560TP
      • MyoDynamics Muscle Strip System - 840MD
    • Organ Bath System >
      • Organ Bath System - 751MT
      • Organ Bath System - 752eT
      • Organ Bath System | 820MO
    • Pressure Myograph Systems >
      • Pressure Myograph System - 110PXL
      • Pressure Pulsation Myograph System - 112PP
      • Pressure Myograph System - 114P
      • Pressure Myograph System - 114PB
      • Pressure Myograph System - 114PN
      • Pressure Myograph System - 120CP
    • Wire Myograph Systems >
      • Single Wire Myograph System - 320A
      • Confocal Wire Myograph System - 360CW
      • Dual Wire Myograph System - 420A
      • Multi Wire Myograph System - 620M
      • Automated Multi Myograph System - 630MA
    • Myograph Software >
      • MyoNORM
      • MyoDAQ Acquisition
      • MyoVIEW 5
      • MyoPULSE
    • Accessories & Parts >
      • Buffer Filler System
      • FlowMeter - 162FM
      • Stimulators >
        • Stimulator - CS4+
        • Stimulator - CS8
  • Resources
    • DMT Academy >
      • Product Videos
      • Practical Guides
      • Protocols & Articles
    • Guides & Manuals
    • Training/Installation
    • System Maintenance
    • Software Downloads
  • DMT Insights
    • Latest News
    • Lab Spotlight
    • Installation Stories
  • About us
  • Contact
Pressure Pulsation Myograph System – 112PP

Pressure, flow and pulsation studies in small isolated vessels

The DMT 112PP is a pressure and pulsation myograph for studying the structure and function of isolated small vessels under near-physiological conditions. It supports constant transmural pressure, non-pulsatile luminal flow workflows and pulsation simulation from 50 to 600 BPM, allowing researchers to investigate pressure, mechanical stretch, vessel diameter and functional vascular responses in one system.

Request quote Download data sheet Compare pressure systems
50–600 BPM Programmable pulsation simulation.
Vessels >40 µm Cannulated small-vessel preparations.
MyoVIEW ready Live diameter, pressure and vessel-wall analysis.
DMT Pressure Pulsation Myograph System 112PP
112PP Dynamic pressure and pulsation workflows
Why choose 112PP

Designed for pressure myography when pulsation and mechanical stretch matter

The 112PP extends standard pressure-myograph workflows with dynamic pulsation control, longitudinal force measurement and live vessel-dimension analysis.

01

Pulsation simulation

Simulate pulsations between 50 and 600 BPM with a pressure difference of up to 60 mmHg.

02

Pressure, stretch and diameter

Study small vessels under controlled intravascular pressure while measuring vessel diameter and pressure-dependent responses.

03

Longitudinal force

Record longitudinal force alongside pressure and diameter for a more complete mechanical characterization.

04

Low chamber volume

A minimum chamber volume of 3.1 mL helps reduce buffer and reagent consumption.

05

Integrated system control

Heating, pressure control, reservoir operation and calibration are managed through the Pressure Interface.

06

MyoVIEW analysis

Track diameter, lumen, wall thickness, pressure and calculated vascular parameters during the experiment.

System overview

Dynamic pressure-myograph studies with pulsatile pressure control

A small isolated vessel is cannulated, aligned and maintained under controlled transmural pressure while vessel diameter and wall parameters are tracked continuously.

The pulsation chambers allow dynamic pressure patterns to be applied in addition to steady-pressure protocols. The system can also support non-pulsatile flow measurement when configured with the DMT FlowMeter – 162FM.

Constant pressure Study vessels under stable transmural pressure from 0 to 250 mmHg.
Pulsatile protocols Simulate pulse rates from 50 to 600 BPM.
Pressure amplitude Apply pulsation pressure differences of up to 60 mmHg.
Longitudinal force Measure axial vessel force independently from pressure control.
Optional flow measurement Add FlowMeter – 162FM for non-pulsatile flow measurement from 15 to 4,000 µL/min.
System components

Chamber, interface and complete 112PP system

The 112PP combines a pulsation-specific chamber, Pressure Interface and MyoVIEW-compatible acquisition for controlled pressure, pulsation, force and vessel-dimension studies.

DMT 112PP pulsation chamber

112PP chamber

Acid-resistant chamber for cannulated vessel mounting, pulsation control, in-line pressure measurement, longitudinal force recording and optical visualization.

DMT Pressure Interface for the 112PP

Pressure Interface

Touch-screen control of pressure, pulsation, heating, calibration and reservoir functions, with USB communication and analogue outputs.

Complete DMT 112PP pressure pulsation myograph system

Complete 112PP system

Integrated chamber and interface platform for steady-pressure, pulsatile-pressure and MyoVIEW-compatible small-vessel studies.

Research applications

Myogenic response, pulsation and vascular mechanics

The 112PP is relevant for studies where intact pressurized vessels must be assessed under static pressure, dynamic pressure or non-pulsatile flow conditions.

Pulsatile pressure Myogenic tone Flow-mediated dilation Mechanical stretch Compliance Vascular stiffness Hypertension Atherosclerosis Endothelial function
01

Pulsatile pressure studies

Evaluate vessel responses under programmable dynamic pressure conditions and pulse rates.

02

Myogenic responses

Study pressure-dependent constriction and dilation under controlled steady or pulsatile pressure.

03

Flow-mediated dilation

Investigate flow-dependent endothelial function in non-pulsatile flow workflows.

04

Compliance and stiffness

Apply cyclic pressure changes to assess vascular compliance, mechanical adaptation and stiffness.

05

Pharmacological testing

Apply vasoactive compounds to the superfusate or luminal solution and track changes in vessel diameter and tone.

06

Longitudinal vessel mechanics

Combine axial force measurement with pressure and diameter data during vessel-stretch protocols.

Selected scientific publications

112PP in peer-reviewed research

Selected peer-reviewed research that explicitly reports use of the DMT 112PP Pressure Pulsation Myograph.

Pulse pressure and endothelial function

High pulse pressure impairs cerebral artery endothelial function in young, but not old, mice

Experimental Gerontology · 2023 · Mouse posterior cerebral arteries

Posterior cerebral arteries were placed in a DMT 112PP pulsatile pressure myograph chamber and exposed ex vivo to static, low-pulse- pressure and high-pulse-pressure conditions to investigate endothelial dilation and vascular stiffness.

View publication
Publications are provided as examples of peer-reviewed research in which the DMT 112PP was explicitly reported. Inclusion does not imply endorsement of the authors, institutions, conclusions or experimental methods by DMT.
DMT MyoVIEW live vessel tracking software
MyoVIEW workflow

Live diameter tracking and pressure-myograph analysis

MyoVIEW records vessel-wall thickness, vessel and lumen diameter, intravascular pressure and calculated vascular parameters during steady-pressure, flow and pulsation studies.

Live vessel detection Track vessel diameter and lumen changes continuously during the experiment.
Multiple scanlines Use multiple edge-detection zones for robust vessel measurements.
Protocol markers Mark compounds, pressure steps, pulse changes and other interventions during acquisition.
Calculated parameters Review wall thickness, area, flow, vascular resistance, shear stress and related outputs.
View MyoVIEW Software downloads
Technical data

Key 112PP specifications

Core chamber, vessel, pulsation, pressure, force, temperature and communication specifications for evaluating the 112PP.

Flow measurement is available in non-pulsatile modes using FlowMeter – 162FM. Flow cannot be measured during pulsation, so the planned experimental protocol should be defined before quotation.
Chamber
Number of chambers
1
Minimum chamber volume
3.1 mL
Chamber material
Acid-resistant stainless steel
Vessel size
>40 µm
Vessel alignment
X, Y and Z
Micrometer resolution
0.01 mm
Mounting type
Glass or stainless-steel cannulas
Pulsation
Pulse-rate range
50–600 BPM
Pulsation pressure difference
Up to 60 mmHg
Temperature
Temperature range
15.0–50.0 °C
Resolution
0.1 °C
Stability
±0.2 °C
Integrated heating
Yes
Longitudinal force
Output reading
mN
Force range
±200 mN
Force resolution
0.01 mN
Force calibration
Yes
Pressure
Output reading
mmHg
Pressure range
0–250 mmHg
Pressure stability
±0.5 mmHg
Pressure resolution
0.1 mmHg
Reservoir and output
Reservoir
Heated, 250 mL
Pressure circuit
Closed
Air inlet
1 bar maximum
Data communication
USB 2.0
Analogue outputs
4 channels, ±2.5 V
Configuration guidance

Plan the complete pressure and pulsation workflow

The correct 112PP configuration depends on vessel size, microscope and camera setup, pulsatile or steady-pressure protocol, non-pulsatile flow requirements, cannula selection, software and training needs.

Need-to-have equipment

Typical workflows include MyoVIEW acquisition, computer package, inverted microscope, high-speed monochrome camera, stage micrometer, vacuum package and heating bath or circulator.

Flow and mounting options

Confirm glass or stainless-steel cannula sizes, pressure tubing, peristaltic pump requirements and FlowMeter – 162FM for non-pulsatile flow measurement.

Service and training

Installation, vessel-cannulation training, pressure and force calibration guidance, spare pressure transducers and service coverage help support reliable use.

Frequently asked questions

Common questions about the 112PP

What is the Pressure Pulsation Myograph 112PP used for?

The 112PP is used to study small blood vessels under physiologically relevant pressure and pulsatile conditions. It allows researchers to measure vascular function, vessel diameter, compliance, and pressure-dependent responses while simulating the pulsatile environment found in vivo.

What types of blood vessels can be studied with the 112PP?

The 112PP is designed for small arteries and veins greater than 40 µm in diameter. It is ideal for resistance vessel studies where pressure, pulsation, flow, and vascular function are critical to the experiment.

What measurements can the Pressure Pulsation Myograph 112PP perform?

The system measures vessel diameter, wall thickness, intravascular pressure, longitudinal force, myogenic responses, compliance, vascular stiffness, and pressure-dependent changes in vessel function. With MyoVIEW software, researchers can also analyze lumen diameter, shear stress, vascular resistance, and other calculated vascular parameters.

Can the 112PP simulate pulsatile blood flow?

Yes. The 112PP can simulate physiological pulsation rates from 50 to 600 BPM with programmable pressure amplitudes, allowing researchers to investigate how pulsatile pressure influences vascular function, remodeling, compliance, and endothelial responses.

Can the 112PP be used to study myogenic tone and flow-mediated dilation?

Yes. The 112PP is designed for studies of myogenic tone, flow-mediated dilation, endothelial function, mechanical stretch, vascular stiffness, and pharmacological responses under controlled pressure conditions. Optional FlowMeter integration also supports non-pulsatile flow experiments.

What research applications is the 112PP best suited for?

The 112PP is widely used in hypertension, vascular biology, atherosclerosis, endothelial dysfunction, arterial stiffness, cardiovascular disease, pharmacology, and translational vascular research where realistic pulsatile conditions are important for understanding vascular physiology.

What's the difference between the 112PP and the 114P Pressure Myograph?

Both systems study small pressurized blood vessels, but the 112PP adds programmable pulsation simulation and longitudinal force measurement, making it ideal for researchers investigating dynamic vascular mechanics. The 114P is the standard pressure myograph for steady-pressure studies of vascular function and reactivity.

Is the Pressure Pulsation Myograph 112PP the right system for my research?

The 112PP is the best choice if your research requires physiologically relevant pulsatile pressure, vascular mechanics, compliance, or myogenic response studies. If your experiments focus on standard pressure myography without pulsation, the DMT 114P may provide the functionality you need with a simpler workflow.

Resources

112PP documentation and supporting resources

Use the official DMT documentation and related pages when evaluating, configuring or operating the 112PP.

PDF

112PP product data sheet

Product overview, applications, specifications and configuration guidance.

→
PDF

112PP/114P user manual

Detailed setup, pressure circuit, interface and calibration documentation.

→
PDF

112PP/114P user guide

Practical reference for routine pressure-myograph operation.

→
PDF

MyoVIEW user manual

Software documentation for vessel tracking and pressure-myograph analysis.

→
VIEW

MyoVIEW software

Live vessel tracking and analysis for pressure-myograph workflows.

→
FLOW

FlowMeter – 162FM

Optional flow measurement for non-pulsatile pressure-myograph protocols.

→
CMP

Pressure comparison chart

Compare pulsation, flow, force, imaging and vessel-size capability.

→
SUP

Training and installation

Plan setup, cannulation, calibration and practical user onboarding.

→
Configuration guidance

Planning a pulsatile pressure-myography study?

Share the vessel type and size, pressure range, desired pulse rate and pressure amplitude, steady or pulsatile protocol, longitudinal force requirements, non-pulsatile flow needs, microscope and camera setup and preferred analysis workflow. DMT can help define the appropriate 112PP configuration.

Request a quote Ask DMT for guidance

Products

  • Wire Myographs
  • Pressure Myographs
  • Organ Bath Systems
  • Muscle Strip Systems

Resources

  • DMT Academy
  • Product Videos
  • How-to Videos
  • Protocols & Articles
  • Software Downloads

Support

  • Guides & Manuals
  • Training
  • System Maintenance
  • Ask for Advice

Company

  • About DMT
  • Contact
  • Terms & Conditions
  • Software License
  • Privacy Policy
  • Warranty

Contact

  • Contact DMT Denmark
  • Contact DMT USA
  • Regional contacts

© 2026 Danish Myo Technology A/S

Websites supporting climate projects
  • Products
    • Muscle Strip Systems >
      • Tissue Puller System - 560TP
      • MyoDynamics Muscle Strip System - 840MD
    • Organ Bath System >
      • Organ Bath System - 751MT
      • Organ Bath System - 752eT
      • Organ Bath System | 820MO
    • Pressure Myograph Systems >
      • Pressure Myograph System - 110PXL
      • Pressure Pulsation Myograph System - 112PP
      • Pressure Myograph System - 114P
      • Pressure Myograph System - 114PB
      • Pressure Myograph System - 114PN
      • Pressure Myograph System - 120CP
    • Wire Myograph Systems >
      • Single Wire Myograph System - 320A
      • Confocal Wire Myograph System - 360CW
      • Dual Wire Myograph System - 420A
      • Multi Wire Myograph System - 620M
      • Automated Multi Myograph System - 630MA
    • Myograph Software >
      • MyoNORM
      • MyoDAQ Acquisition
      • MyoVIEW 5
      • MyoPULSE
    • Accessories & Parts >
      • Buffer Filler System
      • FlowMeter - 162FM
      • Stimulators >
        • Stimulator - CS4+
        • Stimulator - CS8
  • Resources
    • DMT Academy >
      • Product Videos
      • Practical Guides
      • Protocols & Articles
    • Guides & Manuals
    • Training/Installation
    • System Maintenance
    • Software Downloads
  • DMT Insights
    • Latest News
    • Lab Spotlight
    • Installation Stories
  • About us
  • Contact