Four-channel parallel design
Four chambers allow vessels or tissue rings to be studied simultaneously, supporting repetitive concentration-response protocols and treatment-control comparisons.
The DMT 620M is a robust four-channel wire myograph for in vitro studies of vascular structure and function. It supports isometric contraction and relaxation studies using small arteries, larger vessels and a broad range of tissue ring preparations.
The 620M is designed for laboratories that need a flexible, durable and practical wire myograph for concentration-response curves, compound testing and parallel studies of individual vessel segments.
Four chambers allow vessels or tissue rings to be studied simultaneously, supporting repetitive concentration-response protocols and treatment-control comparisons.
Jaw and pin mounts support work with small vessels as well as larger ring segments, providing flexibility across different tissues and experimental protocols.
Built-in heating, individual gas inflow and chamber drainage help maintain stable experimental conditions across all four channels.
Passive length-tension relationships can be determined following mounting and equilibration to improve consistency between vessel segments and experiments.
The interface provides calibration functions, analogue output channels and USB communication for compatible DMT acquisition workflows.
Multiple 620M systems can be arranged side by side, particularly when combined with the Buffer Filler System – 625FS for expanded experimental capacity.
The 620M is designed for experiments in which isometric force is the principal endpoint. Separating direct measurements from calculated outcomes helps researchers select the correct platform and analysis workflow.
Each chamber records the force generated by a mounted vessel or tissue preparation while its length is held constant.
Recorded force traces can be used to derive commonly reported vascular reactivity outcomes.
The 620M does not directly measure vessel diameter, intraluminal pressure or luminal flow. These endpoints normally require a pressure-myograph system.
Each 620M myograph unit has a centrally positioned, acid-resistant stainless-steel chamber. Tissue supports, either jaws or pins, are located inside the chamber with one side attached to the force transducer and the other to a precision micrometer.
During experiments, compounds can be added directly to the individual baths while contraction and relaxation are measured under isometric conditions.
The 620M is suited to studies of vascular contraction, relaxation and reactivity in small arteries, larger vessels and other ring-mounted preparations.
Its four-chamber format supports concentration-response protocols, compound testing and experiments where individual preparations need to be studied in separate baths.
Evaluate endothelium-dependent and endothelium-independent relaxation following precontraction of the vessel preparation.
Measure active force development and relaxation under controlled isometric conditions.
Run repeated pharmacological protocols across four independent experimental chambers.
Support ring-mounted small-vessel preparations using the appropriate jaw mounting configuration.
Study aorta, carotid artery, trachea, intestine, bladder and related ring-mounted tissue preparations.
The following peer-reviewed studies illustrate how researchers have used the DMT 620M for vascular reactivity, endothelial-function and smooth-muscle investigations across different tissues and disease models.
Second-order mesenteric arteries were mounted in a DMT 620M to assess contractile responses and endothelium-dependent relaxation following P. gingivalis exposure and cinnamaldehyde treatment.
View publicationHuman mesenteric artery rings from organ donors were studied using a DMT 620M to examine sigma-receptor modulation of phenylephrine-induced contraction.
View publicationScaffold-free vascular tissue rings were mounted in a DMT 620M to quantify endothelin-1-mediated contraction and evaluate functional smooth-muscle differentiation.
View publicationAortic segments were studied using a DMT 620M as part of a translational investigation into endothelial dysfunction, vascular reactivity and atherosclerosis.
View publicationPublications are selected to demonstrate representative applications of the 620M. Inclusion does not imply author endorsement of DMT or its products.
Select the acquisition route that best matches the laboratory's software, existing hardware and preferred analysis workflow.
Connect the 620M to a compatible computer through USB and acquire all four force channels in DMT MyoDAQ for recording, display and export.
Learn about MyoDAQStream the four force channels directly into LabChart 8 through USB using the appropriate DMT integration and a compatible LabChart configuration.
Four independent ±2.5 V analogue outputs allow the force signals to be recorded with compatible external data-acquisition hardware.
LabChart, PowerLab and other third-party hardware or software are supplied separately unless specifically included in the quotation. DMT can confirm the appropriate interface for the intended acquisition route.
The 620M workflow combines four myograph chamber units with the shared Multi Interface for environmental control, calibration and communication with the selected data-acquisition setup.
Supports ring-mounted vessel segments using jaw or pin mounting, with precision mechanical adjustment and sensitive isometric force measurement.
Provides shared control of heating, gassing, drainage, selectable force range, calibration and direct data communication across all four channels.
DMT product and how-to videos provide practical guidance for system setup, calibration, mounting, normalization and maintenance.
Overview of the 620M and its principal components.
Guidance for preparing the 620M for experimental use.
Calibration guidance for consistent force measurement.
Mount changes, alignment and vessel-mounting guidance.
Manual normalization and micrometer-adjustment guidance.
Routine cleaning, maintenance and transducer guidance.
Core chamber, temperature, transducer and output specifications for planning a complete 620M installation.
Final contents depend on the selected mounting configuration and quotation. Separate standard system elements, optional DMT equipment and laboratory-supplied infrastructure when planning the installation.
Four myograph chamber units, the Multi Interface, selected mounting supports, system cabling and standard accessories are specified in the quotation.
Options may include the Buffer Filler System – 625FS, alternative jaws and pins, volume-reducing inserts, tungsten wire, spare transducers, installation, training, service agreements and extended warranty.
Typical supporting infrastructure includes a compatible computer, dissection microscope and tools, gas supply, vacuum source, buffer and reagents, and any third-party acquisition hardware selected for the workflow.
Yes. Small arteries can be mounted using the appropriate jaw configuration, provided the vessel dimensions and handling requirements are compatible with the selected setup.
Yes. Larger vessel rings can be mounted using pin supports selected for the preparation size.
Yes. The chambers are separate, allowing different compounds, concentrations or experimental conditions to be applied independently.
No. Normalization is performed manually by adjusting the micrometer according to the selected procedure. Laboratories requiring automated normalization should consider the DMT 630MA.
Yes. The system supports direct streaming of all four force channels into LabChart 8 through USB using the appropriate DMT integration and a compatible LabChart configuration. The signals can alternatively be recorded through the analogue outputs.
Not when the validated direct USB-to-LabChart workflow is used. A PowerLab or other compatible acquisition system may be used when recording from the analogue outputs.
Yes. The 625FS is compatible with the 620M and can support buffer handling in expanded multichannel workflows.
No. The 620M measures isometric force. A pressure myograph is normally used when vessel diameter is the primary endpoint.
Use the product data sheet, manuals, normalization guidance and software resources when evaluating, configuring or operating the 620M.
Current product overview, applications and technical specifications.
→ PDFDetailed system setup, calibration and maintenance information.
→ PDFPractical reference for routine preparation and system use.
→ PDFDMT guidance for wire-myograph normalization workflows.
→ SWFind DMT acquisition software, installers and related tools.
→ DOCBrowse additional DMT product and application documentation.
→ DMTCompare DMT wire-myograph platforms and measurement workflows.
→ SUPSupport laboratory onboarding and consistent system operation.
→