DMT
  • Products
    • Muscle Strip Systems >
      • Tissue Puller System - 560TP
      • MyoDynamics Muscle Strip System - 840MD
    • Organ Bath System >
      • Organ Bath System - 751MT
      • Organ Bath System - 752eT
      • Organ Bath System | 820MO
    • Pressure Myograph Systems >
      • Pressure Myograph System - 110PXL
      • Pressure Pulsation Myograph System - 112PP
      • Pressure Myograph System - 114P
      • Pressure Myograph System - 114PB
      • Pressure Myograph System - 114PN
      • Pressure Myograph System - 120CP
    • Wire Myograph Systems >
      • Single Wire Myograph System - 320A
      • Confocal Wire Myograph System - 360CW
      • Dual Wire Myograph System - 420A
      • Multi Myograph System - 620M
      • Automated Multi Myograph System - 630MA
    • Myograph Software >
      • MyoNORM
      • MyoDAQ Acquisition
      • MyoVIEW 5
      • MyoPULSE
    • Accessories & Parts >
      • Buffer Filler System
      • FlowMeter - 162FM
      • Stimulators >
        • Stimulator - CS4+
        • Stimulator - CS8
  • Resources
    • DMT Academy >
      • Product Videos
      • Practical Guides
      • Protocols & Articles
    • Guides & Manuals
    • Training/Installation
    • System Maintenance
    • Software Downloads
  • DMT Insights
    • Latest News
    • Lab Spotlight
    • Installation Stories
  • About us
  • Contact
Pressure Myograph Accessory

Ultra-low flow measurement for pressurized vessel studies

The DMT FlowMeter – 162FM enables fast, calibrated measurement of ultra-low liquid flow through intact tubular preparations such as arteries, veins and small ducts under dual pressure control. When combined with a compatible DMT pressure myograph and MyoVIEW, it connects vessel-diameter changes with real-time flow, shear stress and vascular resistance.

Request quote Ask about compatibility View pressure systems
15–4,000 µL/min Flow range for small-vessel and tubular-tissue studies.
CMOS technology Stable volume-based liquid-flow measurement.
MyoVIEW integration Real-time flow and derived vascular parameters.
Flow measurement add-on DMT FlowMeter 162FM for ultra-low liquid flow measurement
Why choose 162FM

Add calibrated flow data to pressure-myograph experiments

Vessel diameter alone does not always describe the complete functional response. The 162FM adds a direct flow measurement that can be interpreted together with pressure, vessel dimensions and experimental interventions.

01

Ultra-low flow measurement

Measure liquid flow from 15 to 4,000 µL/min in arteries, veins, small ducts and other tubular preparations.

02

Stable volume-based technology

CMOS-based volume measurement supports stable and accurate readings in vascular research workflows.

03

Temperature compensated

Flow data are calibrated and temperature-compensated by the internal microcontroller.

04

Pressure-myograph integration

Add flow to compatible DMT pressure-myograph workflows without changing the underlying cannulated-vessel approach.

Why flow matters

Interpret vessel diameter together with functional flow

During a pressure-myograph experiment, the vessel may constrict or dilate in response to pressure, luminal flow or a pharmacological intervention. Adding direct flow measurement helps establish how those diameter changes affect fluid movement through the vessel.

MyoVIEW can combine diameter, pressure and flow measurements to support real-time calculation of vascular resistance and shear stress.

Flow rate Measure liquid movement through the mounted tubular preparation in real time.
Diameter response Relate changes in vessel lumen and external diameter to the measured flow response.
Shear stress Use MyoVIEW to calculate shear-related values from flow and vessel-dimension data.
Vascular resistance Evaluate how pressure, vessel diameter and flow combine to determine functional resistance.
Dual pressure control Measure flow through tubular tissues while controlling pressure on both sides of the preparation.
DMT FlowMeter 162FM product view
Product overview

Compact flow measurement for DMT pressure myographs

The 162FM is an add-on instrument for laboratories that require direct flow measurements alongside vessel diameter and pressure data.

Its internal electronics provide calibrated, temperature-compensated output for integration into the DMT pressure-myograph and MyoVIEW workflow.

Measurement direction Ultra-low liquid mass flow through intact tubular tissues.
Typical preparations Arteries, veins, small ducts and other cannulated tubular samples.
Measurement principle CMOS-based technology measuring liquid volume.
Data handling Calibrated and temperature-compensated by an internal microcontroller.
Software context MyoVIEW display and analysis of flow-related vascular data.
Core functions

Flow measurement for advanced pressure-myograph studies

The FlowMeter adds a functional measurement dimension to experiments where pressure and vessel diameter alone are not sufficient.

Low-flow precision

Designed for ultra-low liquid-flow measurements in the range relevant to small vessels and ducts.

Volume-based measurement

CMOS technology measures liquid volume to provide stable flow readings during vascular experiments.

Calibrated output

Data are processed, calibrated and temperature-compensated by the internal microcontroller.

MyoVIEW integration

Display real-time flow rates corresponding to pressure and vessel diameter changes.

Derived vascular values

Combine flow and diameter measurements to support shear-stress and vascular-resistance calculations.

Fluid compatibility

Chemical resistance and fluid biocompatibility support vascular research buffers and intact non-coagulating blood.

Research applications

Flow-dependent function in intact tubular preparations

The 162FM is intended for experiments where flow must be measured directly while the tissue remains cannulated and exposed to controlled pressure.

Flow-mediated dilation Shear stress Vascular resistance Endothelial function Resistance arteries Small ducts Pressure gradients Pharmacology
01

Flow-mediated dilation

Investigate vessel-diameter responses to controlled luminal flow and changing shear conditions.

02

Endothelial function

Evaluate flow-dependent endothelial responses in intact pressurized arteries and veins.

03

Vascular resistance

Combine pressure, vessel diameter and measured flow to assess functional resistance.

04

Shear-stress studies

Use measured flow and vessel dimensions to support real-time shear-stress calculations.

05

Flow-related pharmacology

Assess how vasoactive compounds affect vessel diameter and functional liquid flow.

06

Tubular-tissue studies

Measure ultra-low flow through small ducts and other compatible tubular tissue preparations.

MyoVIEW workflow

Connect flow with vessel diameter and pressure

MyoVIEW provides the software context for displaying and interpreting FlowMeter data together with pressure-myograph measurements.

View MyoVIEW Software downloads
Real-time flow Display measured flow continuously during the pressure-myograph experiment.
Vessel diameter Follow vessel and lumen diameter while flow and pressure are changing.
Pressure data Interpret flow in relation to the inlet and outlet pressure conditions.
Shear stress Calculate shear-related values from measured flow and vessel dimensions.
Vascular resistance Calculate resistance using the relevant pressure and flow data.
Experimental markers Mark flow changes, pressure steps, compounds and other interventions during acquisition.
Technical overview

Key 162FM operating information

Core measurement, tissue, software and fluid-compatibility information for evaluating the FlowMeter.

Confirm the pressure-myograph model, pressure-control arrangement, expected flow range, tubing pathway, fluid type and MyoVIEW setup before ordering.
Measurement
Product
FlowMeter – 162FM
Measurement range
15–4,000 µL/min
Measurement principle
CMOS technology measuring volume
Measurement direction
Ultra-low liquid mass flow
Preparations
Typical tissues
Arteries, veins and small ducts
Experimental context
Dual pressure control
System direction
DMT pressure myograph add-on
Data handling
Calibration
Internally calibrated
Temperature compensation
Internal microcontroller
Software context
MyoVIEW
Calculated values
Shear stress and vascular resistance
Fluids
Chemical resistance
Yes
Fluid biocompatibility
Yes
Blood compatibility
Intact non-coagulating blood
System fit

Pressure-myograph workflows with controlled luminal flow

The FlowMeter is intended as an add-on for compatible DMT pressure myographs. The exact configuration depends on the chamber, pressure-control pathway and intended flow protocol.

Standard pressure myography

Pressure Myograph System – 114P

Add direct flow measurement to small-vessel pressure, diameter, force and flow-mediated dilation workflows.

View 114P
Pressure and pulsation

Pressure Pulsation Myograph – 112PP

Use the FlowMeter for compatible non-pulsatile flow measurements within a broader pressure and pulsation research workflow.

View 112PP
Compatibility and configuration should be confirmed with DMT before ordering, particularly for existing installations or protocols involving pulsatile pressure.
Resources

Software, pressure systems and configuration support

Use the confirmed DMT pages below when planning a pressure-myograph and flow-measurement workflow.

QTE

Request a quote

Request pricing for the 162FM or a complete pressure-myograph configuration.

→
DMT

Pressure myograph systems

Review DMT systems for pressurized-vessel, diameter and flow studies.

→
114P

Pressure Myograph – 114P

Review the standard pressure-myograph platform for small-vessel flow studies.

→
112

Pressure Pulsation Myograph – 112PP

Review pressure, pulsation and compatible non-pulsatile flow workflows.

→
VIEW

MyoVIEW software

Review live vessel tracking, flow data and vascular-analysis tools.

→
SW

Software downloads

Find available DMT software installers and related resources.

→
SUP

Training and installation

Plan setup and onboarding for pressure-myograph and FlowMeter workflows.

→
TECH

Technical support

Ask about system compatibility, setup, operation or troubleshooting.

→
Configuration guidance

Adding flow measurement to a pressure-myograph experiment?

Share the DMT pressure-myograph model, vessel type and diameter, expected flow range, pressure conditions, fluid type, tubing pathway and MyoVIEW setup. DMT can confirm compatibility and define the appropriate 162FM configuration.

Request a quote Confirm compatibility
Products
Wire Myographs Pressure Myographs Organ Bath Systems Muscle Strip Systems
Resources
DMT Academy Product Videos How-to Videos Protocols & Articles Software Downloads
Support
Guides & Manuals Training System Maintenance Ask for Advice
Company
About DMT Contact Terms & Conditions Privacy Policy Warranty
Contact

Contact DMT Denmark

Contact DMT USA

Regional contacts

© 2026 Danish Myo Technology A/S
Websites supporting climate projects
  • Products
    • Muscle Strip Systems >
      • Tissue Puller System - 560TP
      • MyoDynamics Muscle Strip System - 840MD
    • Organ Bath System >
      • Organ Bath System - 751MT
      • Organ Bath System - 752eT
      • Organ Bath System | 820MO
    • Pressure Myograph Systems >
      • Pressure Myograph System - 110PXL
      • Pressure Pulsation Myograph System - 112PP
      • Pressure Myograph System - 114P
      • Pressure Myograph System - 114PB
      • Pressure Myograph System - 114PN
      • Pressure Myograph System - 120CP
    • Wire Myograph Systems >
      • Single Wire Myograph System - 320A
      • Confocal Wire Myograph System - 360CW
      • Dual Wire Myograph System - 420A
      • Multi Myograph System - 620M
      • Automated Multi Myograph System - 630MA
    • Myograph Software >
      • MyoNORM
      • MyoDAQ Acquisition
      • MyoVIEW 5
      • MyoPULSE
    • Accessories & Parts >
      • Buffer Filler System
      • FlowMeter - 162FM
      • Stimulators >
        • Stimulator - CS4+
        • Stimulator - CS8
  • Resources
    • DMT Academy >
      • Product Videos
      • Practical Guides
      • Protocols & Articles
    • Guides & Manuals
    • Training/Installation
    • System Maintenance
    • Software Downloads
  • DMT Insights
    • Latest News
    • Lab Spotlight
    • Installation Stories
  • About us