Economical system format
Focus the configuration on pressure, diameter, wall and optional flow endpoints without paying for longitudinal force measurement.
The DMT 114PN is a pressure myograph for experiments on pressurized small arteries, veins and other vessels under near-physiological conditions. It is designed for researchers who need static-pressure, vessel-diameter or flow-related studies without longitudinal force measurement, providing a more economical pressure-myograph configuration.
The 114PN retains the core pressure, cannulation, heating and vessel-tracking workflow of the 114P while omitting the force transducer and associated positioning mechanism.
Focus the configuration on pressure, diameter, wall and optional flow endpoints without paying for longitudinal force measurement.
Study intact vessels under controlled transmural pressure and add the FlowMeter – 162FM where flow measurement is required.
Mount small arteries, veins and other vessels between two cannulas while preserving tubular vessel geometry.
Maintain chamber temperature without relying on continuous superfusion as the only heating method.
Stainless-steel construction supports routine cleaning and helps reduce adhesion of lipids and compounds.
Measure vessel and lumen diameter, wall thickness, pressure and calculated vascular parameters throughout the protocol.
A small intact artery or vein is mounted onto two cannulas and pressurized to the required transmural pressure. This preserves tubular vessel geometry while allowing diameter, lumen, wall dimensions and pressure-dependent responses to be monitored.
Compared with the 114P, the 114PN removes longitudinal force measurement. It is therefore suited to experiments where vessel diameter, wall structure, pressure response or flow-related function are the relevant endpoints.
The 114PN chamber is designed for mounting pressurized vessels between two cannulas. Integrated pressure transducers, XYZ alignment and an optical base window support controlled pressure, visualization and flow-related studies.
The 114PN is suited to studies where the biological question depends on the behavior of an intact pressurized vessel and longitudinal force measurement is not required.
Study pressure-dependent constriction and dilation under controlled transmural pressure.
Investigate endothelial responses to controlled luminal flow when configured with a FlowMeter.
Measure diameter changes following luminal or abluminal exposure to vasoactive compounds.
Track vessel and lumen dimensions during controlled pressure steps.
Calculate flow-dependent parameters when the system is paired with the relevant flow workflow.
The 114PN workflow combines a cannula-based pressure chamber, pressure-control interface and software for live tracking and analysis.
Cannula-based chamber for pressurized-vessel studies without longitudinal force measurement.
Interface with heated reservoir, touch-screen pressure control, calibration procedures, chamber heating and direct data communication.
Software workflow for live vessel detection, dimension tracking, pressure acquisition and pressure-myograph calculations.
MyoVIEW collects vessel-wall thickness, vessel and lumen diameter, intravascular pressure and calculated parameters throughout pressure, flow and pharmacological protocols.
Core chamber, pressure, temperature, reservoir and communication specifications for evaluating the 114PN.
The appropriate configuration depends on vessel dimensions, microscope and camera compatibility, cannula format, pressure circuit, optional flow measurement, software requirements and laboratory training needs.
Typical workflows include MyoVIEW, computer package, inverted microscope, camera, stage micrometer, vacuum package, heating bath or circulator, dissection microscope, light source and dissection tools.
Confirm cannula dimensions, pressure tubing, peristaltic pump requirements and FlowMeter – 162FM where flow measurement is part of the protocol.
Installation, cannulation training, pressure calibration, leak testing, spare pressure transducers and maintenance coverage help support consistent operation.
Use the official DMT documents and related pages when evaluating, configuring or operating the 114PN.
Product overview, applications and technical specifications.
→ PDFDetailed system setup, pressure circuit, interface and calibration documentation.
→ PDFPractical reference for mounting and routine system operation.
→ PDFSoftware documentation for pressure-myograph tracking and analysis.
→ VIEWLive vessel tracking and analysis for DMT pressure myographs.
→ FLOWOptional flow measurement for compatible pressure-myograph protocols.
→ CMPCompare the 114PN with other DMT pressure-myograph systems.
→ SUPPlan system setup, cannulation, calibration and user onboarding.
→Share the vessel type and diameter, pressure range, flow needs, microscope and camera setup, cannula preference and intended MyoVIEW analysis. DMT can help confirm whether the 114PN is the appropriate pressure-myograph configuration.