DMT
  • Products
    • Isolated Heart System >
      • Langendorff System - 900L
    • Muscle Strip Systems >
      • Tissue Puller System - 560TP
      • MyoDynamics Muscle Strip System - 840MD
    • Organ Bath System >
      • Organ Bath System - 751MT
      • Organ Bath System - 752eT
      • Organ Bath System | 820MO
    • Pressure Myograph Systems >
      • Pressure Myograph System - 110PXL
      • Pressure Pulsation Myograph System - 112PP
      • Pressure Myograph System - 114P
      • Pressure Myograph System - 114PB
      • Pressure Myograph System - 114PN
      • Pressure Myograph System - 120CP
    • Wire Myograph Systems >
      • Single Wire Myograph System - 320A
      • Confocal Wire Myograph System - 360CW
      • Dual Wire Myograph System - 420A
      • Multi Wire Myograph System - 620M
      • Automated Multi Myograph System - 630MA
    • Myograph Software >
      • MyoNORM Normalization
      • MyoDAQ Acquisition
      • MyoHEART Acquisition
      • MyoVIEW Acquisition & Analysis
    • Accessories & Parts >
      • Buffer Filler System
      • FlowMeter - 162FM
      • Stimulators
  • Resources & Support
    • Product Videos
    • How-to Videos
    • Protocols & Articles
    • Guides & Manuals
    • Software Downloads
    • Training/Installation
    • System Maintenance
  • DMT Insights
  • About us
  • Contact
Introducing DMT 900L

DMT Langendorff
System 900L

The heart of the experiment.

An integrated platform for isolated-heart perfusion. Bring perfusion, pressure measurement and electronic temperature control together—and configure the cardiac measurements your protocol needs.

Discuss your protocol →Download data sheet →
Constant pressure or pump-controlled flowMouse · rat
DMT Langendorff System 900L with separate perfusion pump
DMT Langendorff 900L shown with separate perfusion pump.
900L at a glancePerfusion modesSystem & optionsApplicationsControl & acquisitionTechnical detailsMethods & resources
900L at a glance

The Langendorff essentials, configured for your study.

The 900L focuses on the core requirements of isolated mouse and rat heart perfusion, with optional cardiac measurements selected to suit the protocol. It is designed for laboratories that need a practical, configurable Langendorff platform rather than every specialized feature available on more complex systems.

PreparationIsolated mouse and rat hearts
Perfusion modesConstant pressure or pump-controlled constant flow
TemperatureElectronic perfusion-pathway and chamber heating
PressureAortic/perfusion pressure monitoring
Ventricular functionOptional left ventricular pressure (LVP)
Electrical studiesOptional ECG and pacing
AcquisitionMyoHEART, LabChart 9 or analogue outputs
Coronary flowSeparate external or in-line measurement when required
One platform · two perfusion modes

Choose how you perfuse.
Define what you observe.

Retrograde aortic perfusion for isolated mouse and rat hearts. Select the perfusion mode in software to match the research question.

Constant pressure

Hold perfusion pressure.

Coronary flow can respond.

Investigate the heart at a defined perfusion pressure. Changes in vascular resistance can alter coronary flow.

Pump-controlled constant flow

Set the perfusion flow.

Perfusion pressure can respond.

Use calibrated pump delivery to define flow while following pressure responses as vascular resistance changes.

Pump flow and coronary-flow measurement are different. Pump delivery is controlled and calibrated. Measuring actual coronary flow during constant-pressure perfusion requires a suitable external or in-line flow measurement solution.

Integrated by design

Built around the preparation.

The platform coordinates perfusion, pressure and electronic heating around a free-hanging or submerged heart. Built-in heating controls the perfusion pathway and heart chamber without an external circulating water bath.

Core platform

Perfusion, pressure & temperature

  • Retrograde aortic Langendorff perfusion.
  • Constant-pressure or pump-controlled constant-flow operation.
  • Aortic / perfusion pressure recording.
  • Electronic perfusion-pathway and chamber heating.
  • MyoHEART control and data acquisition, with USB and analogue acquisition connections.
Optional measurement packages

Add the endpoints you need.

  • LVP: intraventricular balloon pressure for ventricular-function studies.
  • ECG: Wilson-coupled recording with Leads I, II and III.
  • Pacing: selectable voltage or current output.
  • Coronary flow: external or in-line measurement integration when required.
Connected DMT Langendorff perfusion unit and pump
Connected perfusion setup · tubing and preparation access.
DMT Langendorff pump module
Pump module · controlled perfusion delivery.
DMT cardiac interface with ECG and pacer connectors
Optional cardiac interface · ECG connections and pacing output.

Images show selected configurations. The quotation defines the supplied components, preparation format and optional measurement packages.

Research applications

From perfusion to cardiac physiology.

Select the measurement packages and experimental conditions for your study.

Contractility and ventricular mechanics
With LVP: assess ventricular pressure and derive LVDP, LVEDP, +dP/dt and −dP/dt using an appropriate analysis workflow.
Ischemia–reperfusion
Apply defined perfusion protocols to investigate injury, recovery and protective interventions.
Cardiac pharmacology
Evaluate acute responses to compounds under controlled ex vivo perfusion conditions.
Cardiotoxicity research
Investigate changes in mechanical or electrical cardiac responses with the relevant measurement packages.
ECG and pacing
Study electrical activity and responses to controlled pacing when the required options are included.
Temperature-dependent function
Examine cardiac responses under defined perfusion-pathway and chamber temperature conditions.
Control & acquisition

Keep control and recording connected.

MyoHEART control & acquisition

Control the 900L and acquire physiological signals in one workspace. MyoHEART brings perfusion settings, temperature, pressure and the selected cardiac measurements together around your experiment.

Available signals and pacing functions depend on the connected hardware and optional measurement packages.

Explore MyoHEART →

Alternative acquisition routes

Use LabChart 8 through USB with the DMT Device Enabler, or connect the eight analogue BNC outputs to PowerLab or other compatible acquisition hardware.

DMT can confirm software licensing, integration and channel requirements for your existing setup.

Discuss your recording setup →
Technical details & resources

The essentials for planning your setup.

View key technical specifications
Perfusion principle
Retrograde aortic Langendorff perfusion
Species
Mouse and rat hearts
Preparation format
Free-hanging or submerged
Perfusion pressure
0–250 mmHg; 0.1 mmHg resolution
Pump delivery
0–100 rpm; calibrated flow range 0–100 mL/min
Temperature
Perfusion pathway and heart chamber: 20–50 °C; 0.1 °C resolution
Control & digital acquisition
MyoHEART control and acquisition; alternative USB recording with LabChart 8 and the DMT Device Enabler
Analogue acquisition
8 BNC outputs; −2.5 to +2.5 V

Published instrument ranges are technical limits, not recommended experimental settings. Cannulas, heart size, tubing, pump calibration and measurement packages must match the protocol.

Download the 900L data sheet →
Are LVP, ECG and pacing included as standard?

They are optional packages. The core provides perfusion, pressure and temperature functions. Specify the measurements and pacing requirements when requesting a quotation.

Can I keep my existing PowerLab and LabChart setup?

The analogue outputs support compatible external acquisition hardware, including PowerLab. LabChart recording through USB is also available with the DMT Device Enabler. MyoHEART provides DMT’s control and acquisition workflow. DMT can confirm the appropriate connection and software requirements for your existing equipment.

Is this a working-heart system?

The 900L is purpose-designed for retrograde aortic Langendorff perfusion. It should be selected for isolated-heart Langendorff protocols rather than assumed to provide a working-heart configuration.

What is the difference between constant-pressure and constant-flow Langendorff perfusion?

In constant-pressure mode, the system holds a defined perfusion pressure and coronary flow can change as vascular resistance changes. In pump-controlled constant-flow mode, the pump sets delivery flow and perfusion pressure can change in response to resistance. Pump delivery is not the same as directly measuring coronary flow.

Can the DMT 900L be used for both mouse and rat hearts?

Yes. The 900L is intended for isolated mouse and rat heart preparations. Cannulas, tubing, chamber configuration and experimental settings should be selected for the species and protocol.

Can the 900L record left ventricular pressure and ECG?

Yes, with the appropriate optional packages. An LVP package supports ventricular pressure measurements, while the ECG package supports electrical recordings. Pacing is also optional; these functions should not be assumed to be included in the core configuration.

What software can be used with the 900L?

MyoHEART provides DMT control and acquisition. LabChart 9 can record through USB using the DMT Device Enabler, and eight analogue BNC outputs can connect to compatible external acquisition hardware. Confirm licensing, hardware and channel requirements with DMT.

How does a Langendorff preparation differ from a working-heart preparation?

A Langendorff preparation uses retrograde aortic perfusion of an isolated heart. A working-heart preparation is configured to support a different loading and pumping physiology. The 900L is a Langendorff system, not a working-heart system.

Is the 900L intended for highly specialized Langendorff protocols?

The 900L is designed around common isolated-heart perfusion workflows and configurable measurement options. If your protocol requires specialized capabilities beyond the listed 900L configuration, share those requirements with DMT before selecting a system.

900L user manual · Rev. 1.01 →MyoHEART software →900L product data sheet →Installation & training →Technical support →
Methods & resources

Plan the preparation with confidence.

Explore DMT's documentation library for Langendorff-related application notes and methods background, then use the current 900L data sheet and manual for product-specific configuration.

Important distinction: Some DMT Langendorff application notes were developed for an earlier, more specialized Langendorff platform. They may be useful for general isolated-heart methods, but equipment-specific procedures, features and performance specifications should not be assumed to apply to the 900L.

The 900L is focused on widely used perfusion workflows and selectable measurement packages. For advanced or uncommon requirements, confirm compatibility with DMT before adapting a legacy protocol.

Browse DMT documentation and application notes →

What will your next heart experiment measure?

Share your species, perfusion mode and required endpoints.
We’ll help configure the 900L around your protocol.

Request a quote →Talk to DMT →

Products

  • Wire Myographs
  • Pressure Myographs
  • Organ Bath Systems
  • Muscle Strip Systems
  • Langendorff System

Resources

  • Product Videos
  • How-to Videos
  • Protocols & Articles
  • Software Downloads

Support

  • Guides & Manuals
  • Training
  • System Maintenance
  • Ask for Advice

Company

  • About DMT
  • Contact
  • Terms & Conditions
  • Software License
  • Privacy Policy
  • Warranty

Contact

  • Contact DMT Denmark
  • Contact DMT USA
  • Regional contacts

© 2026 Danish Myo Technology A/S

Websites supporting climate projects
  • Products
    • Isolated Heart System >
      • Langendorff System - 900L
    • Muscle Strip Systems >
      • Tissue Puller System - 560TP
      • MyoDynamics Muscle Strip System - 840MD
    • Organ Bath System >
      • Organ Bath System - 751MT
      • Organ Bath System - 752eT
      • Organ Bath System | 820MO
    • Pressure Myograph Systems >
      • Pressure Myograph System - 110PXL
      • Pressure Pulsation Myograph System - 112PP
      • Pressure Myograph System - 114P
      • Pressure Myograph System - 114PB
      • Pressure Myograph System - 114PN
      • Pressure Myograph System - 120CP
    • Wire Myograph Systems >
      • Single Wire Myograph System - 320A
      • Confocal Wire Myograph System - 360CW
      • Dual Wire Myograph System - 420A
      • Multi Wire Myograph System - 620M
      • Automated Multi Myograph System - 630MA
    • Myograph Software >
      • MyoNORM Normalization
      • MyoDAQ Acquisition
      • MyoHEART Acquisition
      • MyoVIEW Acquisition & Analysis
    • Accessories & Parts >
      • Buffer Filler System
      • FlowMeter - 162FM
      • Stimulators
  • Resources & Support
    • Product Videos
    • How-to Videos
    • Protocols & Articles
    • Guides & Manuals
    • Software Downloads
    • Training/Installation
    • System Maintenance
  • DMT Insights
  • About us
  • Contact