Hold perfusion pressure.
Coronary flow can respond.Investigate the heart at a defined perfusion pressure. Changes in vascular resistance can alter coronary flow.
The heart of the experiment.
An integrated platform for isolated-heart perfusion. Bring perfusion, pressure measurement and electronic temperature control together—and configure the cardiac measurements your protocol needs.

The 900L focuses on the core requirements of isolated mouse and rat heart perfusion, with optional cardiac measurements selected to suit the protocol. It is designed for laboratories that need a practical, configurable Langendorff platform rather than every specialized feature available on more complex systems.
Retrograde aortic perfusion for isolated mouse and rat hearts. Select the perfusion mode in software to match the research question.
Investigate the heart at a defined perfusion pressure. Changes in vascular resistance can alter coronary flow.
Use calibrated pump delivery to define flow while following pressure responses as vascular resistance changes.
Pump flow and coronary-flow measurement are different. Pump delivery is controlled and calibrated. Measuring actual coronary flow during constant-pressure perfusion requires a suitable external or in-line flow measurement solution.
The platform coordinates perfusion, pressure and electronic heating around a free-hanging or submerged heart. Built-in heating controls the perfusion pathway and heart chamber without an external circulating water bath.



Images show selected configurations. The quotation defines the supplied components, preparation format and optional measurement packages.
Select the measurement packages and experimental conditions for your study.
Control the 900L and acquire physiological signals in one workspace. MyoHEART brings perfusion settings, temperature, pressure and the selected cardiac measurements together around your experiment.
Available signals and pacing functions depend on the connected hardware and optional measurement packages.
Explore MyoHEART →Use LabChart 8 through USB with the DMT Device Enabler, or connect the eight analogue BNC outputs to PowerLab or other compatible acquisition hardware.
DMT can confirm software licensing, integration and channel requirements for your existing setup.
Discuss your recording setup →Published instrument ranges are technical limits, not recommended experimental settings. Cannulas, heart size, tubing, pump calibration and measurement packages must match the protocol.
Download the 900L data sheet →They are optional packages. The core provides perfusion, pressure and temperature functions. Specify the measurements and pacing requirements when requesting a quotation.
The analogue outputs support compatible external acquisition hardware, including PowerLab. LabChart recording through USB is also available with the DMT Device Enabler. MyoHEART provides DMT’s control and acquisition workflow. DMT can confirm the appropriate connection and software requirements for your existing equipment.
The 900L is purpose-designed for retrograde aortic Langendorff perfusion. It should be selected for isolated-heart Langendorff protocols rather than assumed to provide a working-heart configuration.
In constant-pressure mode, the system holds a defined perfusion pressure and coronary flow can change as vascular resistance changes. In pump-controlled constant-flow mode, the pump sets delivery flow and perfusion pressure can change in response to resistance. Pump delivery is not the same as directly measuring coronary flow.
Yes. The 900L is intended for isolated mouse and rat heart preparations. Cannulas, tubing, chamber configuration and experimental settings should be selected for the species and protocol.
Yes, with the appropriate optional packages. An LVP package supports ventricular pressure measurements, while the ECG package supports electrical recordings. Pacing is also optional; these functions should not be assumed to be included in the core configuration.
MyoHEART provides DMT control and acquisition. LabChart 9 can record through USB using the DMT Device Enabler, and eight analogue BNC outputs can connect to compatible external acquisition hardware. Confirm licensing, hardware and channel requirements with DMT.
A Langendorff preparation uses retrograde aortic perfusion of an isolated heart. A working-heart preparation is configured to support a different loading and pumping physiology. The 900L is a Langendorff system, not a working-heart system.
The 900L is designed around common isolated-heart perfusion workflows and configurable measurement options. If your protocol requires specialized capabilities beyond the listed 900L configuration, share those requirements with DMT before selecting a system.
Explore DMT's documentation library for Langendorff-related application notes and methods background, then use the current 900L data sheet and manual for product-specific configuration.
Important distinction: Some DMT Langendorff application notes were developed for an earlier, more specialized Langendorff platform. They may be useful for general isolated-heart methods, but equipment-specific procedures, features and performance specifications should not be assumed to apply to the 900L.
The 900L is focused on widely used perfusion workflows and selectable measurement packages. For advanced or uncommon requirements, confirm compatibility with DMT before adapting a legacy protocol.
Browse DMT documentation and application notes →Share your species, perfusion mode and required endpoints.
We’ll help configure the 900L around your protocol.