DMT
  • Products
    • Muscle Strip Systems >
      • Tissue Puller System - 560TP
      • MyoDynamics Muscle Strip System - 840MD
    • Organ Bath System >
      • Organ Bath System - 751MT
      • Organ Bath System - 752eT
      • Organ Bath System | 820MO
    • Pressure Myograph Systems >
      • Pressure Myograph System - 110PXL
      • Pressure Pulsation Myograph System - 112PP
      • Pressure Myograph System - 114P
      • Pressure Myograph System - 114PB
      • Pressure Myograph System - 114PN
      • Pressure Myograph System - 120CP
    • Wire Myograph Systems >
      • Single Wire Myograph System - 320A
      • Confocal Wire Myograph System - 360CW
      • Dual Wire Myograph System - 420A
      • Multi Wire Myograph System - 620M
      • Automated Multi Myograph System - 630MA
    • Myograph Software >
      • MyoNORM
      • MyoDAQ Acquisition
      • MyoVIEW 5
      • MyoPULSE
    • Accessories & Parts >
      • Buffer Filler System
      • FlowMeter - 162FM
      • Stimulators >
        • Stimulator - CS4+
        • Stimulator - CS8
  • Resources
    • DMT Academy >
      • Product Videos
      • Practical Guides
      • Protocols & Articles
    • Guides & Manuals
    • Training/Installation
    • System Maintenance
    • Software Downloads
  • DMT Insights
    • Latest News
    • Lab Spotlight
    • Installation Stories
  • About us
  • Contact
DMT Insights · Lab Spotlight
Lab Spotlight

Measuring What Holds Life Together

Dr. Janine Meienberg and Valeria Turco

Cardiovascular Genetics Inherited Aortic Disease Tissue Puller System
Read the story View all Lab Spotlights
Research area Rare inherited connective tissue disorders.
Experimental preparation Small, delicate murine aortic samples.
Measurement endpoint Maximum force before tissue rupture.
Valeria Turco and Dr. Janine Meienberg in the laboratory
Valeria Turco and Dr. Janine Meienberg Center for Cardiovascular Genetics and Gene Diagnostics, Schlieren-Zurich, Switzerland.

Measuring Strength Where It Matters Most

At the Center for Cardiovascular Genetics and Gene Diagnostics of the Swiss Foundation for People with Rare Diseases in Schlieren-Zurich, Switzerland, research is driven by equal parts scientific rigor and human urgency. Research Associate Dr. Janine Meienberg and Biomedical Analyst Valeria Turco work at the intersection of diagnostics and discovery, focusing on rare inherited connective tissue disorders that weaken the aorta and, in the most severe cases, put lives at constant risk.

Their work centers on conditions such as vascular Ehlers–Danlos syndrome (vEDS) and Marfan syndrome (MFS), diseases that often go undetected until a catastrophic vascular event occurs. What motivates them isn’t only biology, it’s the people behind the mutations.

One project, they recall, began as a request from a patient who simply wanted to help save their family’s lives.

That moment crystallized the lab’s mission: to translate genetic insight into meaningful, testable therapies.

Turning Complex Genetics into Clear Measurements

For those unfamiliar with this field, Janine and Valeria describe their work in refreshingly tangible terms. Using murine models, they recover five aortic segments from each animal and measure the maximum force the tissue can withstand before rupture. This allows them to directly compare healthy versus diseased tissue, as well as treated versus untreated samples at the level of individual vessels.

This approach became especially powerful after a suitable mouse model for vEDS was identified. Originally developed almost by accident in another research group, the model ultimately proved too closely to mimic human disease. With it, Janine and Valeria could finally quantify something clinicians care deeply about but rarely get to see aortic integrity itself.

To do this, the team relies on three DMT Tissue Puller systems , which enable them to test small, delicate aortic samples in liquid while achieving highly reproducible results.

When Results Challenge Assumptions

Some of the lab’s most important contributions came from results that didn’t match expectations.

Losartan, a drug often discussed in the context of inherited aortic diseases, showed no beneficial effect on aortic rupture force in vEDS mice. Even more surprising, in MFS models, losartan reduced aortic diameter but still failed to improve rupture strength.

Perhaps most unexpectedly, the team observed that drug efficacy varied depending on the manufacturer, a finding with real implications for both research reproducibility and clinical translation.

These were not the answers we expected, but they were the answers the data gave us.

From the Bench to the Bigger Picture

The broader goal of this research is clear: expand therapeutic options for patients with inherited aortic diseases, especially through drug repurposing. By identifying existing, market-approved drugs that can increase aortic rupture force, the path from bench to bedside could be dramatically shortened.

Looking ahead five to ten years, Janine and Valeria hope to:

  • Test additional drugs for their effects on aortic strength
  • Investigate new candidate genes linked to aortic phenotypes
  • Continue collaborating with international teams to validate findings across models

Their work sits at a rare and valuable crossroads where diagnostics inform research and research feeds directly back into diagnostics.

Overcoming the Hard Parts

Progress didn’t come easily. One of the biggest early challenges was finding an objective, reliable readout system that could truly distinguish between healthy and diseased aortas. Another was navigating the bureaucratic complexity of animal study approvals, a reality familiar to many researchers.

The breakthrough came with the identification of the tissue puller approach as the right solution.

The system gave us a clear, quantitative answer. Once we had that, everything else could move forward.

Why the DMT Tissue Puller Matters

When asked what stands out about their DMT equipment, the answer is immediate and practical:

  • Ease of use – an intuitive, almost “rustic” start/stop operation
  • Flexibility – compatible with pins, clamps and various tissue sizes
  • Small-sample capability – ideal for murine aorta
  • Reproducibility – robust data with low numbers of animals
  • Liquid testing – essential for physiological relevance, enabled by the DMT 560TP

For Janine and Valeria, the value isn’t just convenience, it’s confidence in the data.

Pride, Perseverance and Advice for the Next Generation

What they’re most proud of isn’t a single publication or dataset, but the fact that their work meaningfully contributes to a small but critically important patient population one that often lacks both visibility and treatment options.

Their advice to aspiring researchers is simple, honest and hard-earned:

  • Be innovative. Don’t be afraid to develop new methods when existing ones fall short.
  • Be persistent. As Valeria puts it: “Never give up. Overcome the challenges you face.”

In a field defined by fragile tissues and high stakes, Dr. Janine Meienberg and Valeria Turco are building something resilient: a framework for understanding, measuring and ultimately strengthening the vessels that matter most.

Dr. Janine Meienberg Lab Spotlight
Dr. Janine Meienberg, Research Associate at the Center for Cardiovascular Genetics and Gene Diagnostics.

Research at a glance

Institution Center for Cardiovascular Genetics and Gene Diagnostics
Location Schlieren-Zurich, Switzerland
Research focus Inherited aortic diseases and connective tissue disorders
Preparation Murine aorta
Measurement Aortic rupture force
DMT system Tissue Puller System – 560TP
Article focus

Measuring aortic integrity in inherited disease

A lab spotlight on inherited aortic diseases, aortic rupture force measurements and the use of DMT Tissue Puller systems for small, delicate aortic samples.

Inherited aortic disease Aortic rupture force Murine aorta DMT Tissue Puller systems
Related DMT resources

Continue exploring DMT tissue systems

Learn more about DMT tissue systems, product videos, manuals and practical support resources.

DMT system

Tissue Puller System – 560TP

Explore the DMT system used for controlled rupture force measurements in small tissue samples.

View system →
Learning resources

DMT Academy

Product videos, how-to content, articles and practical learning resources.

Open Academy →
System guidance

Contact DMT

Ask DMT for help choosing systems, software, training or support.

Contact DMT →
Explore more research stories

Meet more researchers from the DMT community

Explore additional Lab Spotlights covering vascular physiology, pharmacology, cardiovascular research, tissue mechanics and smooth muscle function.

View all Lab Spotlights Contact DMT

Products

  • Wire Myographs
  • Pressure Myographs
  • Organ Bath Systems
  • Muscle Strip Systems

Resources

  • DMT Academy
  • Product Videos
  • How-to Videos
  • Protocols & Articles
  • Software Downloads

Support

  • Guides & Manuals
  • Training
  • System Maintenance
  • Ask for Advice

Company

  • About DMT
  • Contact
  • Terms & Conditions
  • Software License
  • Privacy Policy
  • Warranty

Contact

  • Contact DMT Denmark
  • Contact DMT USA
  • Regional contacts

© 2026 Danish Myo Technology A/S

  • Products
    • Muscle Strip Systems >
      • Tissue Puller System - 560TP
      • MyoDynamics Muscle Strip System - 840MD
    • Organ Bath System >
      • Organ Bath System - 751MT
      • Organ Bath System - 752eT
      • Organ Bath System | 820MO
    • Pressure Myograph Systems >
      • Pressure Myograph System - 110PXL
      • Pressure Pulsation Myograph System - 112PP
      • Pressure Myograph System - 114P
      • Pressure Myograph System - 114PB
      • Pressure Myograph System - 114PN
      • Pressure Myograph System - 120CP
    • Wire Myograph Systems >
      • Single Wire Myograph System - 320A
      • Confocal Wire Myograph System - 360CW
      • Dual Wire Myograph System - 420A
      • Multi Wire Myograph System - 620M
      • Automated Multi Myograph System - 630MA
    • Myograph Software >
      • MyoNORM
      • MyoDAQ Acquisition
      • MyoVIEW 5
      • MyoPULSE
    • Accessories & Parts >
      • Buffer Filler System
      • FlowMeter - 162FM
      • Stimulators >
        • Stimulator - CS4+
        • Stimulator - CS8
  • Resources
    • DMT Academy >
      • Product Videos
      • Practical Guides
      • Protocols & Articles
    • Guides & Manuals
    • Training/Installation
    • System Maintenance
    • Software Downloads
  • DMT Insights
    • Latest News
    • Lab Spotlight
    • Installation Stories
  • About us
  • Contact