Single controlled chamber
Study one mounted vessel segment at a time in a compact, precisely controlled wire myograph chamber.
The DMT 320A is a single-chamber wire myograph for isometric force measurements in ring-mounted vessel preparations from 30 µm to 3 mm. It is suited for focused vascular reactivity, tone, contractility and pharmacology studies where one precisely controlled chamber is the right experimental format.
The 320A is well positioned for focused vessel studies, method development, teaching, fluorescence-compatible observation and laboratories that need a compact entry point into wire myography.
Study one mounted vessel segment at a time in a compact, precisely controlled wire myograph chamber.
A precision micrometer provides direct manual control of vessel circumference and stretch during mounting and normalization.
Designed for small arteries, veins and related smooth-muscle vessel preparations mounted on parallel stainless-steel wires.
The chamber base supports morphological observation or fluorescence measurements with a suitable inverted microscope.
Heating, oxygenation, suction, refilling and solution exchange support stable ex vivo vessel studies.
The Wire Interface supports USB data communication, analogue outputs, calibration and compatible acquisition workflows.
The vessel segment is mounted as a ring preparation by threading it over two parallel stainless-steel wires and securing the wires to two supports or jaws. One support is attached to a precision micrometer, while the other is attached to a force transducer.
During the experiment, vessel circumference is kept constant while contractility and reactivity are measured under isometric conditions. Compounds can be added directly to the chamber.
The 320A supports functional analysis of small vessels under controlled ex vivo conditions where the primary endpoint is force or tension generated by a ring-mounted preparation.
It is especially relevant for vessel tone, contraction, relaxation, dose-response protocols, passive mechanics and fluorescence-compatible observation workflows.
Measure contraction and relaxation responses to pharmacological or physiological stimuli.
Determine passive length-tension relationships after mounting and equilibration.
Use the compact single-channel format for protocol development, teaching and focused experiments.
Use the optical base window for morphological or fluorescence measurements.
The 320A workflow combines a single wire myograph chamber, manual micrometer control, sensitive force measurement and the Wire Interface for heating, calibration and data communication.
Supports one ring-mounted vessel preparation with manual stretch control, force measurement, oxygenation, solution exchange and optical observation.
Provides touchscreen control of heating, force calibration, output configuration and direct digital or analogue data communication.
Core chamber, temperature, transducer and output specifications for planning a complete 320A installation.
The correct 320A configuration depends on vessel type, wire size, microscope setup, acquisition requirements, stimulation needs and available laboratory infrastructure.
Typical complete workflows include acquisition software, a compatible computer, dissection stereo microscope, light source, dissection tools, tungsten wire, heating bath or circulator, vacuum package and gas supply manifold.
Depending on protocol, additions can include an electronic valve for chamber drainage, field-stimulation electrodes, stimulator, pH electrode, pH meter and membrane-potential microelectrodes.
For new users, teaching laboratories or multi-user environments, training, service agreements, spare force transducers and extended warranty can support long-term operation.
Choose the 320A when one controlled chamber is sufficient. Consider another platform when the workflow requires specialized imaging, paired chambers, greater throughput or automated normalization.
Consider the 360CW when close confocal or fluorescence imaging access is central to the experimental workflow.
View 360CWChoose the 420A for two vessel positions, paired comparisons and dual-channel wire myography.
View 420AChoose the 620M for four-channel throughput or the 630MA when automated normalization is a core requirement.
View 620M View 630MAThe 320A is designed to measure isometric force in isolated blood vessels and ring-shaped tissue preparations. It's ideal for focused vascular reactivity, pharmacology, and physiology studies where a single, precisely controlled chamber is all that's needed.
The 320A supports small arteries, veins, and other ring-mounted smooth muscle preparations ranging from approximately 30 µm to 3 mm in diameter. It is commonly used in cardiovascular, vascular biology, and smooth muscle research.
The system measures isometric force, vascular contraction, relaxation, vessel tone, concentration-response relationships, and passive length-tension characteristics. It is designed for precise functional studies of isolated vessel segments under controlled laboratory conditions.
Yes. The 320A is widely used to evaluate vascular reactivity, endothelial function, receptor pharmacology, and drug responses. It's an excellent platform for generating concentration-response curves and studying how blood vessels respond to physiological and pharmacological stimuli.
The 320A is ideal for researchers who need maximum control over a single vessel preparation. It's a great choice for method development, pilot studies, teaching laboratories, and research projects where throughput is less important than precision and simplicity.
The 320A is commonly used in hypertension, diabetes, atherosclerosis, endothelial dysfunction, vascular pharmacology, pulmonary research, and smooth muscle physiology. It is also well suited for protocol development and investigator training.
The 320A is a single-channel system designed for one vessel at a time, making it ideal for focused studies and method development. The 420A features two independent chambers, allowing researchers to compare control and treatment groups simultaneously or run parallel experiments more efficiently.
The 320A is the right choice if you need a compact, high-precision wire myograph for single-vessel studies, teaching, pilot projects, or laboratories with lower sample throughput. If your research requires paired comparisons or higher throughput, consider the 420A or the Multi Myograph 620M.
Use the product data sheet, software, wire-myograph comparison and support pages when evaluating, configuring or operating the 320A.
Product overview, applications and technical specifications.
→ DMTCompare the 320A with other DMT wire-myograph platforms.
→ SWData-acquisition software for DMT wire-myograph workflows.
→ SWFind DMT installers, drivers and acquisition tools.
→ SUPPlan onboarding, training or installation support.
→ SRVReview maintenance and service options for DMT systems.
→ ACCFind supporting equipment for a complete 320A workflow.
→ DMTDiscuss vessel type, wire size, imaging and configuration needs.
→